{"product_id":"elsner-salva-knx-th","title":"Salva KNX TH","description":"\u003cp\u003eSalva KNX TH is a smoke detector sensor for the KNX building bus system. Their compact housing accommodates the sensors, evaluation circuits and bus-coupling electronics. The smoke alarm features an automatic evaluation sensor system for early and accurate fire alarms. Alarms are output as a local acoustic signal and a bus telegram. Salva KNX-TH signals smoke and\/or heat alarm.\u003c\/p\u003e\n\u003cp\u003eAND logic gates and OR logic gates allow for a link between data and statuses. Multi-functional modules change input data as required by means of calculations, querying a condition, or converting the data point type.\u003c\/p\u003e\n\u003cp\u003eThe Salva KNX TH model additionally features integrated sensors for temperature and air humidity. The measured values can be used for the control of limit-dependent switching outputs. The devices have PI controls for heating\/cooling (depending on temperature) and for ventilation (depending on humidity).\u003c\/p\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul class=\"lg:columns-2\"\u003e\n\u003cli\u003eSmoke alarm sensors with optical detection based on the scattered light principle, certified according to EN 14604:2005\/AC:2008 and 1172-CPR-150013. Local acoustic alarm signal output (warning sound at least 85 dB) and transfer to KNX bus. Local alarm acknowledgement\u003c\/li\u003e\n\u003cli\u003eSignalling of smoke alarm\u003c\/li\u003e\n\u003cli\u003eSmoke chamber pollution measurement and pollution display according to UL directive \u003c\/li\u003e\n\u003cli\u003ePower supply via battery (9 V). Lack of battery capacity is signalled optically and acoustically for 30 days and transmitted to the bus\u003c\/li\u003e\n\u003cli\u003eHigh operative safety due to elaborate automatic self-testing of the entire electronics and separate energy measurement\u003c\/li\u003e\n\u003cli\u003eFaults signalled locally and via the bus\u003c\/li\u003e\n\u003cli\u003eHigh deceptive alarm immunity due to powerful measuring chamber and consideration of temperature fluctuations (though no temperature smoke alarm) \u003c\/li\u003e\n\u003cli\u003e8 AND and 8 OR logic gates each with 4 inputs. All switching events as well as 16 logic inputs (in the form of communications objects) can be used as inputs for the logic gates. The output from each gate can be configured optionally as 1-bit or 2 x 8-bit\u003c\/li\u003e\n\u003cli\u003e8 multi-function modules (computers) for changing the input data by calculations, by querying a condition or by converting the data point type\u003c\/li\u003e\n\u003cli\u003e4 actuating variable comparators to output minimum, maximum or average values. 5 inputs each for values received via communication objects\u003c\/li\u003e\n\u003cli\u003eConfiguration via ETS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional functions for Salva KNX TH:\u003c\/p\u003e\n\u003cul class=\"lg:columns-2\"\u003e\n\u003cli\u003eSignalling of heat alarms \u003c\/li\u003e\n\u003cli\u003eTemperature sensor and air humidity sensor with mixed value calculation, dewpoint calculation, comfort field query (DIN 1946)\u003c\/li\u003e\n\u003cli\u003eThreshold values for measured and calculated values, adjustable via parameters or communication objects\u003c\/li\u003e\n\u003cli\u003ePI control for heating\/cooling (depending on temperature)\u003c\/li\u003e\n\u003cli\u003ePI controller for ventilation (depending on air humidity)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Data\u003c\/h4\u003e\n\u003ctable class=\"technicaldata\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eABS, glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eWhite \/ Translucent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection category\u003c\/td\u003e\n\u003ctd\u003eIP 30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eØ approx. 113 mm, height approx. 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 280 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003eOperation -10…+60°C, storage -10°C … +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurrounding air humidity\u003c\/td\u003e\n\u003ctd\u003emax. 90% RH, avoid condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e9 V (battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary supply\u003c\/td\u003e\n\u003ctd\u003eKNX bus voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData output\u003c\/td\u003e\n\u003ctd\u003eKNX +\/- bus connector terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003eSmoke alarm\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection principle\u003c\/td\u003e\n\u003ctd\u003eTyndall effect (optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm display\u003c\/td\u003e\n\u003ctd\u003eoptically (LED red) and \u003cbr\u003eacoustically (signal tone \u0026gt;85 dB(A) \/ 3 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplies with\u003c\/td\u003e\n\u003ctd\u003eEN 14604:2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. monitoring area\u003c\/td\u003e\n\u003ctd\u003e60 m² to 6 m height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir velocity\u003c\/td\u003e\n\u003ctd\u003emax. 20 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse sensitivity\u003c\/td\u003e\n\u003ctd\u003e0.15 dB\/m typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelf life for the alarm\u003c\/td\u003e\n\u003ctd\u003emax. 2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003eTemperature sensor (Salva KNX TH)\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e-10…+60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch3\u003eHumidity sensor (Salva KNX TH)\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0% RH … 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eScope of Supply\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSensor (housing with skirting)\u003c\/li\u003e\n\u003cli\u003e9 V battery\u003c\/li\u003e\n\u003cli\u003e2 screws and dowels for assembly (always use fastening material that is suitable for the material underneath)\u003c\/li\u003e\n\u003cli\u003eData sheet with installation instruction (German, English, French, Italian, Spanish)\u003c\/li\u003e\n\u003cli\u003eManual (German, English, French, Italian, Spanish) as download\u003c\/li\u003e\n\u003cli\u003eProduct file (German, English, French, Italian, Spanish) as download\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Elsner","offers":[{"title":"Default Title","offer_id":56984427987322,"sku":"EL-70406","price":262.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/0926\/7920\/files\/EL-70406.jpg?v=1781700070","url":"https:\/\/myknxstore.co.uk\/products\/elsner-salva-knx-th","provider":"My KNX ","version":"1.0","type":"link"}