{"product_id":"elsner-windancer-2-0-knx-sec","title":"Windancer 2.0 KNX sec","description":"\u003ch4 class=\"headline-xs mb-s4\"\u003eHighlights\u003c\/h4\u003e\n\u003cul class=\"copy-s\"\u003e\n\u003cli class=\"flex mt-s2 first:mt-0\"\u003e\u003cspan\u003eCombines a light sensor\/sun sensor, wind speed sensor, rain sensor and thermometer\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"flex mt-s2 first:mt-0\"\u003e\u003cspan\u003eKNX Data Secure, Smart Linking Ready\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"flex mt-s2 first:mt-0\"\u003e\u003cspan\u003eMade in Germany\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Windancer 2.0 GPS KNX sec weather station for the KNX building bus system measures temperature, wind speed and brightness, and detects precipitation.\u003c\/p\u003e\n\u003cp\u003eIn the ETS application, all values can be used to control threshold-dependent switching outputs. The states can be linked using AND and OR logic gates.\u003c\/p\u003e\n\u003ch4\u003eFunctions\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWind measurement with stable cup anemometer (up to 200 km\/h under laboratory conditions), wind measurements in m\/s, km\/h and Beaufort\u003c\/li\u003e\n\u003cli\u003eBrightness measurement (current illuminance). Measurement with 3 separate sensors (east, south, west). Separate threshold values for night\u003c\/li\u003e\n\u003cli\u003ePrecipitation detection: The sensor surface is heated, so that only drops and flakes are recognised as precipitation, but not mist or dew. When the rain or snow stops, the sensor is soon dry again and the precipitation warning ends\u003c\/li\u003e\n\u003cli\u003eTemperature measurement\u003c\/li\u003e\n\u003cli\u003eKNX Data Secure, extended secure key table (peer-to-peer key table) for \u0026gt; 1,000 keys\u003c\/li\u003e\n\u003cli\u003eIntuitive configuration interface\/menu navigation, context-sensitive help and semantic information (Smart Linking Ready)\u003c\/li\u003e\n\u003cli\u003eA simple roller shutter and blind control can be implemented using threshold values and associated switching outputs. For this purpose, up to three brightness thresholds are defined for each compass direction (east\/south\/west)\u003c\/li\u003e\n\u003cli\u003eAll threshold values can be set via parameters or communication objects\u003c\/li\u003e\n\u003cli\u003eLive data preset: current measured value can be set as a limit value via a communication object (wind, temperature, brightness)\u003c\/li\u003e\n\u003cli\u003eLocation query (Northern\/Southern Hemisphere) controls the correct output of east and west brightness values\u003c\/li\u003e\n\u003cli\u003e8 AND and 8 OR logic gates, each with 4 inputs. All switching events as well as 16 logic inputs (in the form of communications objects) can be used as inputs for the logic gates. The output of each gate can be configured optionally as 1-bit or 2 x 8-bit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Data\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003ewhite\/translucent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly\u003c\/td\u003e\n\u003ctd\u003eon-wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e113 mm × 101 mm × 225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal weight\u003c\/td\u003e\n\u003ctd\u003e≈ 260 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature\u003c\/td\u003e\n\u003ctd\u003e-25...+50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30...+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eKNX bus:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium\u003c\/td\u003e\n\u003ctd\u003eTP1-256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration mode\u003c\/td\u003e\n\u003ctd\u003eS-Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup addresses maximum\u003c\/td\u003e\n\u003ctd\u003e2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssignments maximum\u003c\/td\u003e\n\u003ctd\u003e2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication objects\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e≤ 14 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eKNX-Steckklemme\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor diameter\u003c\/td\u003e\n\u003ctd\u003eØ 0.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStripping length\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuration after bus voltage restoration until data is received\u003c\/td\u003e\n\u003ctd\u003e≈ 5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSupply:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary supply\u003c\/td\u003e\n\u003ctd\u003e20...32 V DC SELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary current [at]\u003c\/td\u003e\n\u003ctd\u003e≤ 60 mA [24 V DC]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSensors:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range temperature\u003c\/td\u003e\n\u003ctd\u003e-25...+50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range wind [at]\u003c\/td\u003e\n\u003ctd\u003e2…30 m\/s [25 °C]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range brightness\u003c\/td\u003e\n\u003ctd\u003e0 Lux … 150 000 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eScope Of Supply\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWeather station\u003c\/li\u003e\n\u003cli\u003e2× Stainless steel pan head screw, WN56, 4×50mm, cross recess\u003c\/li\u003e\n\u003cli\u003e2× dowel S 6\u003c\/li\u003e\n\u003cli\u003e2× DIN 125 washer V2A, A4.3 outer diameter 9 mm\u003c\/li\u003e\n\u003cli\u003eKNX plug-in terminal and plug-in terminal (white\/yellow)\u003c\/li\u003e\n\u003cli\u003eInstallation instruction (English, German, French, Italian, Spanish)\u003c\/li\u003e\n\u003cli\u003eManual German, English, French, Italian, Spanish) as download\u003c\/li\u003e\n\u003cli\u003eApplication (German, English, French, Italian, Spanish)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Elsner","offers":[{"title":"Default Title","offer_id":56976915562874,"sku":"EL-71238","price":311.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/0926\/7920\/files\/71238-1.png?v=1781528230","url":"https:\/\/myknxstore.co.uk\/products\/elsner-windancer-2-0-knx-sec","provider":"My KNX ","version":"1.0","type":"link"}