{"product_id":"schneider-spacelynk-logic-controller","title":"spaceLYnk logic controller","description":"\u003cp\u003e\u003cspan class=\"description__content font-m\"\u003eSpaceLYnk from Schneider Electric is the easiest way to build a complete Building Automation Solutions for commercial segments. Complete Building Automation solution for Small and Medium building with a complete architecture including KNX, DALI Control), Metering (Modbus offer, Smartlink RTU and IP) and boiler management (SSL). Complete Building Automation solution for Large Building with a complete architecture managed by BMS from Schneider Electric and KNX, DALI Control and Metering (Modbus offer, Smartlink RTU and IP). SpaceLYnk can be used in several ways: As a gateway to translate and enable communication between different products. As an aggregator to stock, analyze, and send the data (.csv file for example). As an user interface to display relevant informations on mobile devices. As an event controler that sends email in case of issues. Applications: Logical functions. WEB SCADA visualization for PC and touch-devices. Cross-standard gateway between KNX and Modbus RTU\/TCP. BACnet Server (500 points). Integration with third party devices over RS-232 (IR, AV). Scheduling. Camera streaming. Data logger with trends. Pre-made Modbus templates. Easy bloc programming. Up to 50 users with different login and password. BACnet certified BACnet Application Specific Controller (B-ASC). New icons. Supply voltage: 24 V DC. Power consumption: 2 W. LED indicator 1: Green LED (CPU load). LED indicator 2: Green LED (Operation) or Red LED (Reset). Interface: 1x KNX, 1x10BaseT\/100BaseTX, 1x RS-485 (incl. Polarization resistors 47 k Ohm, no termination),1x RS-232, 1x USB2.0, 1x Reset push button. Terminal: KNX bus: Bus connecting terminal 2 x 0.8 mm. Power supply: Clamp, 0.5 mm²-1.5 mm². Serial: Clamp, 0.5 mm²-1.5 mm². Operation: -5°C to +45°C. Environment: Can be used at elevations up to 2000 m above sea level (MSL). Max. humidity: 93 %, no condensation. Dimension: 90 x 52 x 58 mm (HxWxD). Device width: 3 modules, approx. 54 mm. Note: Visualisations can be generated automatically for smartphone, tablet and touch panels using the EConfigure KNX Lite (LSS900100) software.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan class=\"description__content font-m\"\u003eTechnical Data\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable class=\"specifications-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eCommunication port protocol\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eModbus\u003cbr\u003eIP (Internet Protocol)\u003cbr\u003eBACnet\u003cbr\u003eKNX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003e[Us] rated supply voltage\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003ePower consumption in W\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e2 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eLED indicator\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eLED (green) for CPU load\u003cbr\u003eLED (green\/red) for KNX powered\/reset\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003ePhysical interface\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e1 x RJ45\u003cbr\u003e1 x RS485\u003cbr\u003e1 x RS232\u003cbr\u003e1 x TP-UART2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eMaximum number of users\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e50\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eNumber of Modbus server\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e31\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eNumber of BACnet tags\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e2000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eIntegrated connection type\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e1 USB 2.0 port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eControl type\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eRESET push-button\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003ePort Ethernet\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e10BASE-T\/100BASE-TX\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eMounting support\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eDIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eConnections - terminals\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eKNX bus: bus terminal 2 cable(s) 0.8 mm²\u003cbr\u003ePower supply: clamp terminal1.5 mm²\u003cbr\u003eSerial: clamp terminal1.5 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":56603607761274,"sku":"LSS100200","price":1579.04,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0598\/0926\/7920\/files\/LSS100200_iop_1500.jpg?v=1771432162","url":"https:\/\/myknxstore.co.uk\/products\/schneider-spacelynk-logic-controller","provider":"My KNX ","version":"1.0","type":"link"}