The Gira eNet wireless switching/momentary-contact/blind actuator receives telegrams for switching lighting or controlling hangings, e.g. blinds, shutters, or awnings, from the Gira eNet wireless reception module or the Gira eNet Server via a data line.
Features
- The eNet wireless switching, wireless momentary-contact, or blind actuator receives telegrams for switching lighting or controlling electrically-operated hangings from the eNet wireless reception module or eNet server via a data cable.
- Two outputs are each operated in the same mode (switching, dimming, blind or shutter).
- Switching of lighting or single-phase fan motors.
- Control of electrically operated hangings, such as blinds, shutters, or awnings
- Operating modes: switching actuator, momentary-contact actuator can be set for a single output; a blind actuator, shutter actuator can be set for a pair of outputs.
- Status feedback to eNet wireless transmitter.
- Scene operation.
- Operating mode buttons: Relay contact stays closed as long as telegrams are being received (max. 60 seconds).
- Positioning of blind and slat using scene call-up.
- Positions for sun protection and twilight can be saved.
- Threshold value scenes for sun protection, twilight and wind alarms.
- Hanging period can be saved.
- Slat adjustment time can be saved.
Can be set with eNet server:
- Flashing function.
- Delay time.
- Switch-on/off delay.
- Switch-off pre-warning.
- Minimum switching repeat time.
- Permanent-on, permanent-off.
- Adjustment time when changing directions.
- Motion direction can be inverted (e.g. for roof windows).
- Position for sun protection, twilight, lock-out protection, and wind alarms.
Technical data
- Rated voltage: AC 230 V, 50/60 Hz
- Standby: max. 0.5 W
- Ambient temperature: -5 °C to +45 °C
- Switching capacity AC 230 V: 16 A / AC1
- Connected load
- Light bulbs: 2300 W
- HV halogen lamps: 2000 W
- Wound transformer: 1000 VA
- Tronic transformer: 1500 W
- Fluorescent lamps, uncompensated: 920 VA
- LED lamps: typ. 500 W
- Compact fluorescent lamp: typ. 500 W
- Motors: 1000 W
- Capacitive load: 690 VA (560 µF)
- Connections: max. 4 mm²
- Length of the data cable: Max. 3 m
Notes
- An eNet wireless reception module or an eNet server is required to operate this DIN-rail mounting device.