Intended use
- Controlling electrically driven blinds, shutters and awnings
- Operation with suitable eNet radio transmitters
- Operation with power supply (ref.-no. NT1220REGVDC) and receiver module (ref.-no. FMFK32REG) or eNet server
- Mounting on DIN rail according to EN 60715 in distribution boxes
Product characteristics
- Operating mode switch for switch-over to blind actuator, shutter actuator or parameterisation via eNet server
- Positioning of the blind and slats via light scene recall
- Position for sun protection and twilight can be saved
- Status feedback to radio transmitter
- Switchable output with Prog button
- Blind/shutter running time can be saved
- Slat change-over time can be saved
- Fabric-stretching for awnings
- Status indication with LED
Can be set with eNet server:
- Change-over time for direction change
- Running direction invertible
- Operating locks
- Position for sun protection, twilight, lock-out protection and wind alarm
Supplementary functions with eNet server:
- Fully-encrypted radio transmission (AES-CCM) from eNet Server software version 2.0
- Update of the device software
- Reading of error memory
Technical data
| Rated voltage: |
AC 230 V ~, 50/60 Hz |
| Ambient temperature: |
−5 ... +45 °C |
| Minimum actuation time in operating mode |
| Blind: |
0.1 s |
| Shutter: |
0.3 s |
| Contact type: |
µ |
| Stand-by power: |
max. 0.2 W |
| Running time: |
1 ... 600 s |
| Running time default setting: |
120 s |
| Slat adjusting time: |
0 ... 10 s |
| Connected load |
| Motors: |
1000 W |
| Connection of load terminals: |
screw terminals |
| single wire: |
1 x 1.5 ... 4 mm² |
| stranded without ferrule: |
1 x 0.75 ... 4 mm² |
| stranded with ferrule: |
1 x 0.5 ... 2.5 mm² |
| Mounting width: |
36 mm (2 rail units) |
| Bus line |
| Rated voltage: |
DC 12 V SELV |
| Current consumption: |
max. 20 mA |
| Connection bus: |
terminal |
| Cable length: |
max. 3 m |
|