Intended use
- Switching and dimming of incandescent lamps, HV halogen lamps, electronic transformers for halogen or LED lamps, dimmable inductive transformers for halogen or LED lamps, HV LED or compact fluorescent lamps
- Operation with power supply (ref.-no. NT1220REGVDC) and receiver module (ref.-no. FMFK32REG) or eNet server
- Operation with suitable eNet radio transmitters
- Mounting on DIN rail according to EN 60715 in distribution boxes
Product characteristics
- Switch-on via bulb-preserving soft start
- Switch-on brightness for each output can be saved permanently
- Minimum brightness for each output can be saved permanently
- Scene operation possible
- Status indication of the outputs via LED
- Status feedback to radio transmitter
- Outputs switchable with Prog button
- Increase in output power possible through parallel switching of multiple outputs
- Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
- Electronic over-temperature protection
- Automatic or manual setting of the dimming principle suitable for the load
- Power extension possible by means of power boosters (ref.-no. ULZ1755REG)
- Optional accessory: compensation module LED, ref.-no.: KMLED230U
Can be set with eNet server:
- Maximum brightness
- Dimming speed
- Switch-on delay / switch-off delay
- Dim up/dim down ramp
- Switch-off warning
- Operating locks
- Continuous on, Continuous off
- Hotel function
- Run-on time
Supplementary functions with eNet server:
- Fully-encrypted radio transmission (AES-CCM) from eNet Server software version 2.0
- Update of the device software
- Reading of error memory
Technical data
Rated voltage: |
AC 230 V ~, 50/60 Hz |
Power loss: |
max. 8 W |
Stand-by power: |
max. 1.2 W |
Ambient temperature: |
−5 ... +45 °C |
Connected load per output at 45 °C |
Power specifications including transformer power dissipation. |
Operate inductive transformers with at least 85 % nominal load. |
For ohmic-inductive mixed load, maximum 50 % proportion of ohmic load. Otherwise incorrect calibration of the dimmer may result. |
Max. load for outputs connected in parallel is limited to 95 %. |
The minimum load of parallel switching of load outputs is 250 VA. |
Incandescent lamps: |
20 ... 250 W |
HV halogen lamps: |
20 ... 250 W |
Electronic transformers: |
20 ... 250 W |
Electronic transformers with LV LED: |
typical 20 ... 100 W |
Inductive transformers: |
20 ... 250 VA |
Inductive transformers with LV LED: |
typical 20 ... 100 VA |
Dimmable HV LED lamps: |
typical 3 ... 50 W |
Dimmable compact fluorescent lamps: |
typical 3 ... 50 W |
With setting "LED trailing edge phase control" the max. connection power for HV LED lamps and electronic transformers with LV LED doubles. |
Ohmic-inductive: |
20 ... 250 VA |
Ohmic-capacitive: |
20 ... 250 VA |
Capacitive-inductive: |
not permitted |
Amplifiers: |
see instructions for amplifier |
Connection, outputs |
Connection mode: |
screw terminals |
single wire: |
1 x 1.5 ... 4 mm² |
stranded without ferrule: |
1 x 0.75 ... 4 mm² |
stranded with ferrule: |
1 x 0.5 ... 2.5 mm² |
Contact type: |
ε |
Length of output cable, per channel: |
max. 100 m |
Mounting width: |
144 mm (8 rail units) |
Bus line |
Rated voltage: |
DC 12 V SELV |
Current consumption: |
10 mA |
Connection bus: |
terminal |
Cable length: |
max. 3 m |
|